top of page

Choosing the Right Fall Arrest Safety Net for Skylights Roof Edges and Open Stairwells EN1263-1 Checklist

Oct 29
3 min read

A fall through a rooflight, slab edge, or stairwell opening happens fast. The right safety net does one job well: it catches a falling person before the fall becomes fatal. For contractors, the challenge is choosing a net that fits the risk, the structure, and the work sequence, while meeting EN 1263-1 requirements.


EN 1263-1 covers safety net performance and testing. It should sit alongside a site-specific risk assessment, installation plan, and, where relevant, EN 1263-2 guidance on positioning and installation.


Wide-angle view of a safety net installed beneath roof skylights on a construction site
Skylight work needs fall protection that accounts for fragile surfaces and access routes.

Start with the fall hazard, not the net


Different openings need different thinking.


Skylights and rooflights are often fragile, especially on older roofs. A net below the opening can reduce the consequence of a fall, but it must sit close enough to limit fall distance and clear enough to prevent impact with beams, services, or stored materials.


Roof edges need protection where collective edge systems are not enough, incomplete, or being installed. Nets may support the wider fall protection plan, but they must not create a false sense of security at unprotected edges.


Open stairwells and floor voids need careful fixing points. Loads may transfer into concrete, steel, timber, or temporary works, so the support structure matters as much as the net.


Check the EN 1263-1 basics


A compliant fall-arrest safety net should come with clear identification and traceability. Ask for the label, documentation, and test evidence before it reaches site.


Check

What to look for

Standard

Marking or certification showing EN 1263-1 compliance

Net system

Correct system type for the application, such as horizontal safety netting for voids

Mesh and class

Suitable mesh size and energy absorption class for the intended fall risk

Border rope

Correct border rope strength and condition

Test mesh

Test samples available for ageing and UV checks where required

Inspection record

Evidence of pre-use, periodic, and post-incident checks

Manufacturer guidance

Installation limits, repair rules, and retirement criteria


Do not accept an unlabelled net because it “looks fine”. Age, UV exposure, chemical contact, cuts, and poor storage can all weaken netting.


Match the net to the structure


A net is only as good as the way it is fixed. Before ordering, confirm:


  • The opening size and shape

  • The likely fall height

  • The available clearance below the net

  • Anchor point locations and strength

  • Any sharp edges that could damage ropes

  • Nearby services, rebar, ductwork, or protrusions

  • Access for installation, inspection, and removal


For skylights, plan around roof fragility and loading. For stairwells, check that fixings do not clash with follow-on trades. For roof edges, confirm whether the net is part of temporary works and who signs off the design.


Inspect before use and after anything unusual


A quick visual check is not enough if the net has moved, been struck, or sat exposed for months. Build inspection into the daily site routine.


Look for:


  • Broken or cut mesh

  • Damaged stitching or knots

  • Frayed border ropes

  • Heat, paint, chemical, or welding damage

  • Loose ties or incorrect lacing

  • Excessive sag

  • Missing labels

  • Debris caught in the net


If a person, heavy tool, or material load falls into the net, take it out of service until a competent person confirms what happens next.


Close-up view of a safety net label and border rope fixed to a steel frame
Labels, ropes, and fixings should be checked before the net is accepted for use.

Use this contractor checklist before ordering


Before the net arrives on site, confirm these points in writing:


  1. The hazard is defined

    Skylight, roof edge, stairwell, floor void, or combined risk.


  1. The standard is specified

    EN 1263-1 compliance is stated in the procurement documents.


  2. The system type is suitable

    The chosen net system matches the opening, position, and support method.


  1. Fall clearance has been checked

    The net will arrest the fall without allowing impact below.


  2. Anchors are designed or verified

    Fixings and support structures can take the imposed loads.


  1. Installation is planned

    Competent installers have drawings, access, and a safe method.


  2. Inspection is assigned

    Someone competent owns pre-use and ongoing checks.


  1. Rescue is planned

    A fallen worker can be recovered quickly and safely.


A safety net is not a last-minute site accessory. It is part of the temporary works and fall protection plan. Choose it early, check the paperwork, verify the fixings, and inspect it throughout the job. That is how EN1263-1 becomes a practical site control, not just a line in a specification.


 
 
bottom of page